environment temperature threshold

Description                                                    Configure the temperature condition under which a log is generated.

Syntax                                                                  [no] environment temperature threshold low num medium num high num

Parameter

Description

low num

Low temperature threshold in Celcius; a log is generated when the temperature drop below this threshold.

medium num

Medium temperature threshold in Celcius.This threshold causes the status in the show environment command to change between “low/med” or “med/high”.

high num

High temperature threshold in Celcius; a log is generated when the temperature rises above this threshold.

Default                                                                Low is 25, medium is 45, high is 68.

Mode                                                                   Configuration mode

Example                                                            Set the low temperature threshold to 20 degress Celcius, medium to 45 degrees Celcius, and high temperature threshold to 55 degrees Celcius:

ACOS(config)#environment temperature threshold low 20 medium 45 high 55

 

The show environment command reflects the new temperature thresholds:

ACOS(config)#show environment

Updated information every 30 Seconds

Physical System temperature:   38C / 100F : OK-low/med

                Thresholds: Low 20 / Medium 45 / High 55

Physical System temperature2:   34C / 93F : OK-low/med

                Thresholds: Low 20 / Medium 45 / High 55

HW Fan Setting: Automatic

Fan1A : OK-med/high     Fan1B : OK-med/high

Fan2A : OK-med/high     Fan2B : OK-med/high

Fan3A : OK-med/high     Fan3B : OK-med/high

Fan4A : OK-med/high     Fan4B : OK-med/high

Fan5A : OK-med/high     Fan5B : OK-med/high

Fan6A : OK-med/high     Fan6B : OK-med/high

Fan7A : OK-med/high     Fan7B : OK-med/high

Fan8A : OK-med/high     Fan8B : OK-med/high

System Voltage 12V              : OK

System Voltage 5V               : OK

System Voltage CPU1 VCORE (1V)  : OK

System Voltage CPU0 VCORE (1V)  : OK

System Voltage AUX 5V           : OK

System Voltage VBAT (3.3V)      : OK

Upper Left Power Unit(Rear View) State: On

Upper Right Power Unit(Rear View) State: On

Lower Left Power Unit(Rear View) State: On

Lower Right Power Unit(Rear View) State: Off

 

In addition, both temperature status indicate “low/med” because the temperatures fall in between the low threshold of 20 and medium threshold of 45.