logging buffered

Description                                                    Configure the event log on the ACOS device.

Syntax                                                                  [no] logging buffered max-messages

Syntax                                                                  [no] logging buffered 
{disable | emergency | alert | critical | error | warning |
notification | information | debugging} 

Parameter

Description

max-messages

Specifies the maximum number of messages the event log buffer will hold. The default buffer size (maximum messages) is 30000.

disable

Disable logging to the monitor.

emergency

Send emergency events (severity level 0—system unusable) to the monitor.

alert

Send alert events (severity level 1—take action immediately) to the monitor.

critical

Send critical events (severity level 2—system is in critical condition) to the monitor.

error

Send error events (severity level 3—system has an error condition) to the monitor.

warning

Send warning events (severity level 4—system has warning conditions) to the monitor.

notification

Send notifications (severity level 5—normal but significant conditions) to the monitor.

information

Send informational messages (severity level 6) to the monitor.

debugging

Send debug level messages (severity level 7) to the monitor.

Default                                                                See descriptions.

Mode                                                                   Configuration mode

Example                                                            The following command sets the severity level for log messages to 7 (debugging):

ACOS(config)#logging buffered debugging

 